QMS SC-100 Guia de Configuração Página 58

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 100
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 57
:(3#
7#$!#$39#

4 Attach the interface card to the controller board.
a Position the interface card so that its I/O connector slides into its opening in
the interface panel and that its 80-pin connector aligns with the 80-pin
connector on the controller board.
b Gently press the interface card down until its connector is fully seated and the
card is secured by the plastic support post(s).
Caution:
Make sure that the connectors on the interface card and controller
board are properly aligned. Damage to the interface card and/or controller
board could result if the pins are misaligned.
5 Secure the interface card to the interface panel with the two screws you
removed earlier.
6 Reinstall the controller board.
Gently slide the controller board into the printer until it is fully seated, and then
tighten the two screws.
7 Reconnect all interface cables.
8 Reconnect the power cord, and turn on the printer.
9 Print a start-up page.
Check that the start-up page lists the interface just installed under “Options.”
...................................................
...................................................
Vista de página 57
1 2 ... 53 54 55 56 57 58 59 60 61 62 63 ... 99 100

Comentários a estes Manuais

Sem comentários